Modules
Modules & connectors · 5 answers
QS-101Design, connectors & modulesDegradation / performance warranty
Field studies show a median loss of about 0.75% per year; a claim depends on the exact terms and test method in that module's warranty.
QS-102Design, connectors & modulesIEC 61215 vs IEC 61730
IEC 61215 is design qualification (performance and durability tests), IEC 61730 is safety; neither predicts lifetime.
QS-111Design, connectors & modulesTemperature coefficient of Pmax
Probably not. At −0.29%/°C, a 440 W module with 65 °C cells makes about 389 W at full sun, by the datasheet coefficient.
QS-113Design, connectors & modulesAzimuth loss
JinkoSolar's manual says about 10–15% of power output at 30° off due south, and 20–30% at 60° off.
QS-114Operation & maintenanceCleaning
Not like that. JinkoSolar says soft cloth, neutral water (pH 6.5–8), no abrasives, and under 675 kPa if a hose or pressure set is used.
German grid rules (EEG 2023)
Design & grid rules · 4 answers
QS-103Meters, CTs & export control60 % feed-in limit
It is 60 % of the installed module power (kWp), measured at the grid connection point, and it lasts only until a smart meter with a control box is installed and tested.
QS-104Grid voltage & grid connectionInbetriebnahme (commissioning date)
Commissioning is the first time the finished, permanently mounted system is switched on with all the equipment needed to make AC power. Producing a little power for testing is not the test the law uses.
QS-131Grid voltage & grid connection25 kWp threshold (§9 EEG)
The 25 kW threshold in §9 EEG counts installed module power (kWp), not inverter power. Solar systems on the same plot or building that are commissioned within 12 consecutive calendar months count as one system for this test.
QS-161Grid voltage & grid connectionPost-20-year system + battery (§25 EEG)
No new inverter is needed for a battery. Keep the old one, switch the system from full feed-in to surplus feed-in, and add an AC-coupled battery behind the meter. Under the EEG, exported power from a post-20-year system is still paid until 31 December 2032, at the annual market value (capped at 10 ct/kWh) minus a marketing fee.
String inverter
Inverters · 4 answers
QS-126Operation & maintenanceRCD nuisance trip
Often not. A 30 mA RCD may trip at only 15 mA, and SolarEdge recommends a 100 or 300 mA type A RCD unless local code needs lower.
QS-127Operation & maintenanceRCD per inverter
Not with the recommended setup. SolarEdge requires one RCD per inverter; Solplanet says a shared RCD must be rated at least the sum, e.g. 200 mA for two.
QS-128Operation & maintenanceExternal RCD needed?
Not always. Solplanet's inverter has an internal all-pole sensitive RCMU (DIN VDE 0100-712), so an external RCD is only needed where local rules require it.
QS-129Operation & maintenanceInverter clearance
For SolarEdge's single-phase compact inverter: 20 cm above, 10 cm below and 10 cm each side, out of direct sun if possible.
PV array
Modules & connectors · 3 answers
QS-121Operation & maintenanceSnow clearing
Usually no. NREL's SAM snow model puts annual energy lost to snow cover at 0% to almost 16% in the continental US; the fall risk is the bigger cost.
QS-122Operation & maintenanceSoiling rainy climates
Usually not for dust alone. NREL puts typical annual soiling losses at about 1–2% where rain is regular, including most of Europe.
QS-124Operation & maintenancePollen soiling
Rain helps but is often not enough. NREL saw up to 15% performance loss at peak pollen season on five North Carolina plants.
Balcony solar kit + EV wallbox (German grid rules, EEG)
Design & grid rules · 1 answer
QS-191Design, connectors & modules800 VA plug-in limit vs. EV minimum charging power
Only as a small top-up. Germany's plug-in solar rule covers kits with up to 800 VA of inverter power. A wallbox maker's manual says many electric cars need at least 1.4 kW to charge at all. So even in full sun, the balcony kit is below that minimum. If the start-up power is set lower, the rest comes from the grid; with a 1.4 kW start-up power (the manual's example), the car doesn't charge below that surplus.
Bifacial modules
Modules & connectors · 1 answer
QS-108Design, connectors & modulesBifacial gain (datasheet vs field)
Usually less than 10% on natural ground. A measured NREL tracker field over grass made +8.9%. The 25% is the top of a datasheet range, not a forecast.
German grid rules (EEG 2023, Solarspitzengesetz)
Design & grid rules · 1 answer
QS-109Meters, CTs & export controlNo feed-in payment at negative prices (§51 EEG)
Yes for systems commissioned from 25 Feb 2025: the feed-in payment drops to zero in every quarter-hour with a negative day-ahead price. Under 100 kW it only starts after the end of the calendar year in which the smart meter (iMSys) is installed, and the lost time is partly added at the end of the 20 years.
Hybrid inverter / battery (example: Alpha ESS)
Hybrid & backup systems · 1 answer
QS-133Meters, CTs & export control~100 W grid import while battery charges
A small, steady import is normal. Battery systems regulate to a small target at the grid point and react with a short delay, so they lean towards a little import rather than accidental export.
Hybrid inverter with grid meter / CT
Inverters · 1 answer
QS-132Meters, CTs & export controlConsumption rises with PV, battery not charging
That is the classic sign that the inverter's grid meter or CT is reading the wrong direction: it sees your solar export as extra import. Have the CT direction, the meter wiring and the phase assignment checked.
MC4 / Stäubli
Modules & connectors · 1 answer
QS-125Design, connectors & modulesCable gland torque
Stäubli's MC4 assembly instruction gives typical cable-gland tightening torque of 3.4–3.5 N·m, with a calibrated torque tool.
Modules / mounting
Modules & connectors · 1 answer
QS-112Design, connectors & modulesVentilation gap
JinkoSolar requires at least 10 cm between the lower edge of the frame and the highest point of the mounting surface.
Modules / strings
Modules & connectors · 1 answer
QS-115Design, connectors & modulesParallel strings and fuses
JinkoSolar's formula is N ≤ fuse rating / Isc + 1. For the JKM440N-54HL4R-B (25 A fuse, 13.80 A Isc) that gives 2.8, so 2 strings.
Perovskite-silicon tandem modules
Modules & connectors · 1 answer
QS-110Design, connectors & modulesIEC 61215 / 61730 for tandems
Some are now certified to IEC 61215 and IEC 61730, but supply is still pilot or early volume, and the first warranties are shorter than for silicon. For a normal rooftop today, silicon is still the safe choice.
PV battery sizing (system design)
Design & grid rules · 1 answer
QS-163Design, connectors & modulesBattery size: HTW Berlin rules of thumb
No. HTW Berlin's rules of thumb cap usable battery capacity at 1.5 kWh per kWp of PV and at 1.5 kWh per 1,000 kWh of yearly use, whichever is lower. Beyond that, each extra kWh adds very little self-sufficiency.
PV connectors
Modules & connectors · 1 answer
QS-099Design, connectors & modulesMC4 cross-mating
No. Mated PV connectors should be the same type from the same manufacturer; 'MC4 compatible' is not a certification.
PV module
Modules & connectors · 1 answer
QS-123Design, connectors & modulesIEC hail minimum
IEC 61215-2:2021 MQT 17 minimum is 25 mm ice balls (optionally larger). Sinovoltaics' reading of the standard table gives 23.0 m/s for 25 mm.
String design
Design & grid rules · 1 answer
QS-098Design, connectors & modulesCold-weather PV overvoltage
Design the string on its coldest-day open-circuit voltage, not the label value: it must stay below the inverter's maximum DC input voltage.
String inverter with 2 MPPTs (example: Huawei)
Inverters · 1 answer
QS-135Strings, optimisers & microinvertersPartial shade: optimisers vs MPPT layout
Start with the free fixes: put shaded and unshaded modules on separate MPP trackers if your voltage allows, and turn on the inverter's global MPP scan. Only then judge optimisers, using your own yield data.
System design
Design & grid rules · 1 answer
QS-100Design, connectors & modulesDC/AC ratio and clipping
Oversizing the DC side is normal practice; the hard limits are the inverter's own maximum DC input values in its datasheet.
Missing an answer for General & standards? Use the search above to send it to the research queue. We find a real thread and a primary source — nothing goes live until it is checked.