Ask a question
QS-135 · Strings, optimisers & microinverters

In autumn the lower row of my modules and a chimney shadow shade part of my single string on a Huawei inverter. Would retrofitting optimisers help, or do the bypass diodes already do that job?

The short answer
Start with the free fixes: put shaded and unshaded modules on separate MPP trackers if your voltage allows, and turn on the inverter's global MPP scan. Only then judge optimisers, using your own yield data.

Plain explanation

When part of a string is shaded, the bypass diodes switch the shaded cell groups out of the string, but the string then has more than one power peak. SMA's technical note on shade explains that a normal MPP tracker only looks near its current operating point. It can stick on the lower peak unless a global search (SMA: OptiTrac Global Peak; Huawei's app lists a similar MPPT multi-peak scanning setting) is switched on. SMA's design rules: with only a few shaded modules (e.g. under 10 %) a special control isn't needed. If shading is severe, run shaded and unshaded modules separately, with a separate MPP tracker for each string, and use the global peak search. SMA says the search costs at most 0.2 % in times without shade. The function is off by default. For a roof where a whole lower row is shaded, the obvious first step is one string for the top row and one for the bottom row on the inverter's two trackers, if each string still reaches the inverter's MPPT voltage range. Optimisers can recover some energy from part-shaded modules, but low winter sun means the extra kWh are small. Check per-string yield before and after the changes before you pay for hardware.

Steps from the source

  1. Check the inverter has a free second MPPT and that each half-string stays within its MPPT voltage range (cold and hot)
  2. Re-wire into two strings by shade pattern (top row / bottom row): installer job
  3. Enable the inverter's global/multi-peak MPP scan (off by default on SMA; check your Huawei settings)
  4. Compare string yields over a few weeks; only then decide whether optimisers on the shaded modules are worth it
"If shading is severe, it makes sense to operate the shaded and unshaded PV modules separately."

Word for word from the source.

Source

SMA Solar Technology, Technical Information 'Shade Management – Efficient Operation of Partially Shaded PV Systems with OptiTrac Global Peak' (GlobalPeak-TI-en-12, v1.2), Sections 2 'Shade: A Special Task for the Inverter', 3.2 'Selecting the System Connection', 4 'OptiTrac Global Peak'. SMA document hosted by a distributor (no current copy found on files.sma.de). checked 2026-11-09 (Vilnius)www.europe-solarstore.com ↗

Where installers ask this

General guidance based on the manufacturer's manual or the named source. Always follow the current manual for your exact model and your national code. DC and AC electrical work is for qualified installers only. Not affiliated with or endorsed by any brand named; trademarks belong to their owners.

Get new answers and videos