Plain explanation
Rated power is measured at STC: 1000 W/m² and 25 °C cell temperature. On a roof in summer the cells run much hotter. The JinkoSolar JKM440N-54HL4R-B datasheet gives a Pmax temperature coefficient of −0.29%/°C, so 40 °C above STC costs about 11.6%: 440 W × (1 − 0.0029 × 40) ≈ 389 W. The same datasheet lists 331 W at NOCT (800 W/m², 20 °C air, 1 m/s wind). The 65 °C cell temperature here is an illustration, not a measurement; real cell temperature depends on irradiance, wind and mounting.
Steps from the source
- Compare against irradiance and module temperature, not against the label
- Check the Pmax temperature coefficient when choosing modules (closer to 0 is better)
- Keep ventilation under the modules (see qs-112)
"Temperature coefficients of Pmax -0.29%/°C"
Word for word from the source.