The short answer
Not with the recommended setup. SolarEdge requires one RCD per inverter; Solplanet says a shared RCD must be rated at least the sum, e.g. 200 mA for two.
Plain explanation
SolarEdge's guide states that for multiple inverters an RCD per inverter is required. Solplanet's manual asks for a 100 mA RCD per inverter and says the RCD's rated residual current must be at least the sum of the connected inverters' ratings, so two transformerless inverters need at least 200 mA.
Steps from the source
- Plan one RCD per inverter in the board layout
- If a shared RCD is allowed by the manual, size it to the sum
- Check the specific manual; brands differ
"For multiple inverters, an RCD per inverter is required."
Word for word from the source.
Source
SolarEdge Installation Guide, Single Phase Inverter with Compact Technology, Europe & APAC v1.2 (MAN-01-00488-1.2); Solplanet installation manual ASW6000–10000-S(-A), SolarEdge p.28 note; Solplanet 'Rating of the external residual current device'knowledge-center.solaredge.com ↗
Where installers ask this