Plain explanation
A hybrid inverter decides when to charge the battery from a meter or CT clamp at the grid connection point. If that sensor reads backwards, solar power flowing out to the grid looks like power flowing in. The app then shows house consumption rising by the PV power, and the inverter never sees a surplus to charge the battery with. Makers are clear about the direction. SolaX says the meter goes between the grid and all house loads, and the CT arrow should point towards the inverter. LuxPower warns that a wrongly installed CT makes the display show wrong figures and stops inverter features from working. Some inverters let the installer flip the CT direction in software. SolaX gives a simple test: switch the inverter to OFF, turn on some house loads and read the grid power. If it shows positive, the meter/CT direction is reversed. On three-phase systems, each CT must also sit on the phase its meter channel expects. If the utility meter itself runs backwards while you draw from the grid, that is a separate wiring problem at the meter. Leave the system off and have a registered electrician check it before you run it again (our safety advice).
Steps from the source
- Note what the app shows at night (no PV): house load should match the grid import
- Inverter OFF, house loads ON: grid power must read as import; if it reads the other way, the meter/CT is reversed (SolaX test)
- Check the CT arrow points towards the inverter and the clamp sits between the grid and all loads
- Three-phase: check each CT is on the phase its meter channel expects
- If the utility meter turns backwards while importing, switch the PV and battery off and call the installer or an electrician before running it again
"If positive, then the meter/CT direction is reversed. If negative, then the meter/CT direction is correct."
Word for word from the source.
Source
Where installers ask this
General guidance based on the manufacturer's manual or the named source. Always follow the current manual for your exact model and your national code. DC and AC electrical work is for qualified installers only. Not affiliated with or endorsed by any brand named; trademarks belong to their owners.