Plain explanation
IEA PVPS reports that most recent utility-scale plants use DC to AC ratios between about 1.1 and 1.5, with the array oversized to increase annual energy yield. Some energy is clipped at peak sun, but the inverter runs closer to full power for more hours. For a home system the limit is not a rule of thumb: check the inverter datasheet for maximum PV input power, maximum input current per MPPT and maximum input voltage, and any oversizing the maker allows for the warranty. Local connection rules may also cap the AC export, so check your national code.
Steps from the source
- Read max PV input power, max current per MPPT and max input voltage on the inverter datasheet
- Check the maker's allowed DC/AC oversizing and warranty conditions
- Model clipping losses for the site before deciding
- Check grid connection / export limits with the grid operator
"Most utility-scale plants built in recent years have used DC to AC ratios between about 1.1 and 1.5, with the PV array oversized relative to inverter capacity in order to increase annual energy yield."
Word for word from the source.
Source
Where installers ask this
- DC/AC ratio – how oversized is too oversized? (r/solar)
- reddit.com/r/solar/comments/1mx1nsi/is_clipping_always_the_best_option/
General guidance based on the manufacturer's manual or the named source. Always follow the current manual for your exact model and your national code. DC and AC electrical work is for qualified installers only. Not affiliated with or endorsed by any brand named; trademarks belong to their owners.