SMA Sunny Boy event 3501 insulation failure. How do I locate the ground fault?
Disconnect, measure +/PE, -/PE and +/-, locate the fault, otherwise do an insulation resistance measurement.
7 answers · 2 products. Not affiliated with or endorsed by SMA; trademarks belong to their owners.
We do not invent answers. Leave your question and we will find a real installer thread and a primary source, quote word for word, and publish only after review.
Your question is in the queue. Nothing is published automatically; every new answer is checked against a real source first.
Inverters · 6 answers
Disconnect, measure +/PE, -/PE and +/-, locate the fault, otherwise do an insulation resistance measurement.
Make sure PE is connected to the inverter.
Check grid voltage at the connection point; outside range = grid operator, in range = SMA Service.
Check breaker, AC cable, country data set and grid voltage.
Clean the cooling fins, improve ventilation, keep ambient within limits and out of direct sun.
Check the internet connection and that Webconnect is activated.
Hybrid & backup systems · 1 answer
Check the backup specs, not the grid specs. SMA's own planning guide shows the difference: a three-phase Sunny Tripower Smart Energy (or three Sunny Islands) forms a three-phase backup grid with a rotating field. A single-phase Sunny Boy Smart Energy stays single-phase, even with phase coupling, and then only single-phase loads are allowed.