Plain explanation
A hybrid inverter can be three-phase on the grid side and still give only one phase, or bridged phases, in backup mode. SMA's planning guide for its backup systems has a table row 'Drehfeld im Ersatzstromnetz' (rotating field in the backup grid). For one Sunny Tripower Smart Energy and for three Sunny Island units it says yes: they form a three-phase backup grid with a rotating field. For a single-phase Sunny Island or Sunny Boy Smart Energy it says no: even with phase coupling (bridging L1 to L2 and L3), the backup grid stays single-phase. SMA then warns that if three-phase loads are connected to a single-phase grid through phase coupling, it can't rule out damage to them. With phase coupling, only single-phase loads may be connected, and the neutral conductor must be sized for the current of the single-phase inverter so it isn't overloaded. Power is the second limit. In backup, the Sunny Tripower Smart Energy 5.0 to 10.0 can deliver 6 to 12 kW for under 5 minutes and 10 to 12 kW for under 10 seconds (SMA table). A heat pump compressor and a cooker on the same backup grid can exceed that. So when you compare makers, ask for three things in writing: a three-phase backup output with a rotating field, the power per phase and the allowed unbalanced load, and the short-term overload rating. Then decide which circuits really need backup.
Steps from the source
- In each maker's backup manual or planning guide, look for 'three-phase backup with rotating field' (Drehfeld), not just 'three-phase inverter'
- Check the backup power per phase and the allowed unbalanced load; three flats on one backup grid will be unbalanced
- Check the short-term overload rating against heat pump and cooker start-up
- Never put three-phase loads on a phase-coupled (single-phase) backup grid (SMA warning)
- With phase coupling, have the electrician size the neutral conductor for the single-phase inverter current
"Wenn durch Phasenkopplung 3-phasige Verbraucher mit einem 1-phasigen Stromnetz verbunden sind, kann SMA Solar Technology AG eine Beschädigung der 3-phasigen Verbraucher nicht ausschließen."
Word for word from the source.
Source
Where installers ask this
General guidance based on the manufacturer's manual or the named source. Always follow the current manual for your exact model and your national code. DC and AC electrical work is for qualified installers only. Not affiliated with or endorsed by any brand named; trademarks belong to their owners.