Plain explanation
The Fronius GEN24 Plus operating instructions explain each setting. SoC Minimum / SoC Maximum: in Auto mode they are preset from the battery maker's specs. In Manual mode you may change them, but only after checking with the battery maker. 'In a backup power situation, the set values are not taken into account.' Reserve capacity: capacity kept for backup power. 'The battery does not discharge below the reserve capacity in grid connected mode.' In backup mode the battery discharges down to the battery maker's automatic minimum, not your manual SoC Minimum. So the energy really available for an outage is the slice between your reserve and the maker's minimum. SoC warning level: 'In backup power mode, a warning is emitted when this residual battery capacity is reached.' It does nothing in normal grid operation. Recharging at night: Fronius lists 'Forced re-charging' as an operating state. The inverter recharges the battery to hold the maker's SoC or the set minimum SoC, as protection against deep discharge. The manual doesn't give the trigger step, so we can't confirm the 2% the forum reports. Standby: the battery goes into energy-saving mode within ten minutes only when all the switch-off conditions are met. One condition is that the SoC is at or below the minimum. A separate special case also sends the battery to energy-saving mode: 'If the inverter does not operate for 12 minutes (e.g., fault), or there is an interruption in the electrical connection between the inverter and the battery and there is no backup power mode, the battery switches to energy-saving mode in any case.' In the thread, forum members say the battery doesn't go to standby while backup power is configured; the poster found that PV Point, his backup socket, was switched on, and after he switched it off the battery went to standby again.
Steps from the source
- Decide whether you need backup power; if not, switching off the backup power mode (here: PV Point) lets the battery go to energy-saving mode again
- If you keep backup power, set the reserve capacity high enough for the loads you want in an outage: only the slice above the maker's minimum is usable
- Leave SoC limits on Auto unless the battery maker approves other values
- Use the SoC warning level as an alert for backup operation only
"In backup power mode, a warning is emitted when this residual battery capacity is reached."
Word for word from the source.
Source
Where installers ask this
General guidance based on the manufacturer's manual or the named source. Always follow the current manual for your exact model and your national code. DC and AC electrical work is for qualified installers only. Not affiliated with or endorsed by any brand named; trademarks belong to their owners.