QS-195 · Meters, CTs & export control

I bought a Sungrow SH10T to replace a broken inverter. I was told it can run without a smart meter because I don't have a battery yet. Both strings deliver and it feeds in, but after the self-test the app shows fault code F514. Why?

The short answer
514 is Sungrow's 'Meter Communication Abnormal' alarm: the inverter can't talk to its Smart Energy Meter. With no meter connected, the manual says the inverter still runs normally, but the feed-in power setting doesn't work, and a battery added later could charge but not discharge. The meter ships in the box.

Plain explanation

In the SH5T–SH25T user manual, alarm 514 is 'Meter Communication Abnormal'. The corrective steps: check the communication cable and terminals, reconnect the meter's communication cable, and contact Sungrow if the alarm stays. So F514 without a meter is expected. Section 2.5.3 explains what it means: 'If the Smart Energy Meter is abnormal or not equipped, the inverter will run normally, however, the battery can be charged but not allowed to discharge.' The same sentence goes on to say that the feed-in power setting is then ineffective and the DO function for optimised mode is disabled. Today, with no battery, the inverter feeds in normally, which matches what you see. But if your grid connection needs a feed-in limit, that limit only works with the meter. And once the battery is added, it won't discharge without one. The manual lists one Smart Energy Meter in the box. The DTSU666-20 connects meter A to A2 (COM2 pin 3) and meter B to B2 (COM2 pin 4), with the CT arrows pointing from grid to load. If a meter is connected and 514 still shows, Sungrow's steps are: check the wiring, check the line for open or short circuits, then check that the meter's communication address hasn't been changed (default 254). In the thread, a forum member pointed to an 'Energy Meter Kommunikation aktivieren' switch in the installer menu. We didn't find that wording in this manual, so ask the installer who commissions the unit.

Steps from the source

  1. Confirm the alarm: 514 = Meter Communication Abnormal (inverter keeps running)
  2. Have the Smart Energy Meter from the box installed at the grid connection point: meter A to COM2 A2 (pin 3), B to B2 (pin 4), CT arrows grid to load
  3. If 514 remains with a meter fitted: check the cable for open/short circuits and the meter address (default 254)
  4. Before adding a battery or if a feed-in limit is required: the meter must be working
"If the Smart Energy Meter is abnormal or not equipped, the inverter will run normally, however, the battery can be charged but not allowed to discharge."

Word for word from the source.

Source

Sungrow SH5T/6T/8T/10T/12T/15T/20T/25T user manual SH5_6_8_10_12_15_20_25T-UEN-Ver18-202512, 2.5.3 Energy Management; 4 Unpacking and Storage, delivery list (item L Smart Energy Meter, quantity 1); 6.8.2.1 Smart Energy Meter Connection; 10 Troubleshooting, alarm 514 and 'Meter Communication Abnormal Alarm (Fault Code: 514)'. checked 2026-11-23 (Vilnius)info-support.sungrowpower.com ↗