Plain explanation
In the SH5T–SH25T user manual, alarm 514 is 'Meter Communication Abnormal'. The corrective steps: check the communication cable and terminals, reconnect the meter's communication cable, and contact Sungrow if the alarm stays. So F514 without a meter is expected. Section 2.5.3 explains what it means: 'If the Smart Energy Meter is abnormal or not equipped, the inverter will run normally, however, the battery can be charged but not allowed to discharge.' The same sentence goes on to say that the feed-in power setting is then ineffective and the DO function for optimised mode is disabled. Today, with no battery, the inverter feeds in normally, which matches what you see. But if your grid connection needs a feed-in limit, that limit only works with the meter. And once the battery is added, it won't discharge without one. The manual lists one Smart Energy Meter in the box. The DTSU666-20 connects meter A to A2 (COM2 pin 3) and meter B to B2 (COM2 pin 4), with the CT arrows pointing from grid to load. If a meter is connected and 514 still shows, Sungrow's steps are: check the wiring, check the line for open or short circuits, then check that the meter's communication address hasn't been changed (default 254). In the thread, a forum member pointed to an 'Energy Meter Kommunikation aktivieren' switch in the installer menu. We didn't find that wording in this manual, so ask the installer who commissions the unit.
Steps from the source
- Confirm the alarm: 514 = Meter Communication Abnormal (inverter keeps running)
- Have the Smart Energy Meter from the box installed at the grid connection point: meter A to COM2 A2 (pin 3), B to B2 (pin 4), CT arrows grid to load
- If 514 remains with a meter fitted: check the cable for open/short circuits and the meter address (default 254)
- Before adding a battery or if a feed-in limit is required: the meter must be working
"If the Smart Energy Meter is abnormal or not equipped, the inverter will run normally, however, the battery can be charged but not allowed to discharge."
Word for word from the source.
Source
Where installers ask this
- SH10T ohne Batterie zeigt Fehlercode F514 an (photovoltaikforum.com)
- photovoltaikforum.com/thread/266118-sungrow-dtsu666-offline/
General guidance based on the manufacturer's manual or the named source. Always follow the current manual for your exact model and your national code. DC and AC electrical work is for qualified installers only. Not affiliated with or endorsed by any brand named; trademarks belong to their owners.