At handover, the measured open-circuit voltage of all three strings is about 16% below the calculated value. Modules: LONGi Hi-MO S10 LR7-54HJBB 490 W, Voc 41.25 V (STC), −0.210%/°C. It was a very overcast, rainy day at about 5 °C. The installer says the deviation is completely normal. Is it?

The short answer
Most likely yes, if all strings are low by the same amount per module. The datasheet's 41.25 V applies at 1000 W/m² and 25 °C. On a dark day the irradiance is far lower, and Voc falls with it. Your three strings agree to within about 0.2 V per module, which points to the weather, not a missing module.

Plain explanation

The datasheet value is a lab value. LONGi gives Voc = 41.25 V for the 490 W module at STC, which the datasheet defines as AM1.5, 1000 W/m² and 25 °C, with a Voc temperature coefficient of −0.210%/°C. Correcting only for temperature, as you did, assumes full 1000 W/m² sun. Voc also depends on light. Sandia's PV Array Performance Model writes Voc = Voc0 + Ns·δ·ln(Ee) + βVoc·(Tc − T0). Ee is the effective irradiance relative to 1000 W/m², and Tc is the cell temperature, not the air temperature. On a heavily overcast day Ee is far below 1, so ln(Ee) is negative and Voc drops. The effect is logarithmic, so it's small in bright light and large on a really dark day. Your own numbers are the best test. Per module: south 409 V / 11 = 37.2 V, east 741 V / 20 = 37.1 V, west 666 V / 18 = 37.0 V. Three roof faces, three string lengths, and the same voltage per module. A module that was left unplugged or bridged would show up as one string missing about one module's voltage compared with the others, and that isn't the case here. To close the question, measure again on a clear, sunny day around noon, record the irradiance and module temperature, and compare the strings with each other. Keep the readings with the handover papers.

Steps from the source

  1. Divide each string's measured Voc by its number of modules and compare the strings
  2. If they match each other, low Voc on a dark day is expected; if one string is about one module short, check that string's connections
  3. Re-measure on a clear day around noon and note irradiance and module temperature with the readings
  4. Keep the commissioning readings (Voc per string, insulation resistance) with the handover documents
"STC : AM1.5 1000W/m2 25℃"

Word for word from the source.

Source

LONGi datasheet LR7-54HJBB 490~505M (30-30&15 Frame) BGV02 20250905; Sandia National Laboratories PVPMC, Sandia PV Array Performance Model, Datasheet: Electrical Characteristics (STC, LR7-54HJBB-490M Voc 41.25 V), Temperature Ratings (Voc −0.210%/℃). Sandia SAPM eq. 3 and parameter list https://pvpmc.sandia.gov/modeling-guide/2-dc-module-iv/point-value-models/sandia-pv-array-performance-model/. checked 2026-11-23 (Vilnius)longi-solar.net ↗