Plain explanation
The official EcoFlow PowerPulse Residential EV Charger user manual we used is for PowerPulse model EF-PP-H01-1, which 'can provide 1.38-11kW charging output' (specifications: Model EF-PP-H01-1, AC output max. 11 kW). The poster's 22 kW EcoFlow wallbox is not that model. EcoFlow's PowerPulse 2 datasheet lists 7 kW, 11 kW and 22 kW models. We found the official PowerPulse 2 Installation Guide V1.4 (filename 20261030) and that datasheet on EcoFlow's documentation centre; they do not describe the minimum-charging-amount steps quoted below. EcoFlow also lists a separate PowerPulse 2X 22 kW datasheet there; we did not use it here. So the charging logic below is from the PowerPulse (11 kW) manual, not a PowerPulse 2 user manual. Check the documents for your exact 22 kW model (PowerPulse 2 or PowerPulse 2X) with your installer. That PowerPulse (11 kW) manual describes two setups. In the one where PowerOcean supplies the wallbox, 'Smart Charging' works in two steps. First, you set a minimum charging amount for your daily travel needs, and PowerOcean always gives the wallbox maximum power until it is reached. The manual defines that maximum power as hybrid charging from grid, solar and battery. Second: 'After the minimum charging amount is reached, PowerOcean will prioritize solar energy input for charging power supply.' If solar is then below the minimum charging power, PowerOcean draws from the battery and the grid so charging doesn't stop. So a jump to full power right after plugging in is what the 11 kW manual describes while the car is below the minimum charging amount. Look at that setting in the EcoFlow app before you suspect the wiring. Once solar is in charge, that manual's phase switching applies. If solar plus battery can give less than the three-phase minimum of 4.14 kW, the system switches to single-phase, with a minimum of 1.38 kW. Below 1.38 kW it draws from the grid. In the other setup, where the wallbox runs on its own, it talks to a smart meter (ADL400) over RS485. In solar charging mode it uses solar first, and the grid tops up to keep the current at 6 A or more. In the thread, forum members found no separate smart meter. EcoFlow support then told the owner that his PowerOcean Plus doesn't need one. We could not confirm that support statement in a PowerOcean Plus manual. The PowerPulse 2 Installation Guide V1.4, printed page 12, section '(Optional) Establishing communication with EcoFlow PowerOcean/PowerOcean Plus/OCEAN 2', says: 'In solar storage charging and standalone operation (solar charging or load balancing) scenarios, EcoFlow PowerPulse 2 must communicate with external meter via a shielded twisted pair cable.' The same sentence is in V1.2 and V1.3, also on printed page 12. That guide is for PowerPulse 2, not PowerPulse 2X. Ask EcoFlow or your installer to confirm the metering for your exact 22 kW model in writing.
Steps from the source
- In the EcoFlow app, check the minimum charging amount; in the PowerPulse (11 kW) manual, until it is reached, PowerOcean charges at maximum power
- Lower the minimum charging amount to what you really need each day, then test again on a sunny day
- After the minimum is reached, the PowerPulse (11 kW) manual describes solar-first charging: 1-phase from 1.38 kW, 3-phase from 4.14 kW. Confirm those figures in the documents for your exact 22 kW model (PowerPulse 2 or PowerPulse 2X)
- If it still charges at full power, ask the installer or EcoFlow to confirm how your system measures grid export (meter/CT or not) and that PowerPulse is paired with PowerOcean
"After the minimum charging amount is reached, PowerOcean will prioritize solar energy input for charging power supply."
Word for word from the source.
Source
Where installers ask this
General guidance based on the manufacturer's manual or the named source. Always follow the current manual for your exact model and your national code. DC and AC electrical work is for qualified installers only. Not affiliated with or endorsed by any brand named; trademarks belong to their owners.