Plain English
Label: the 440 W on a JinkoSolar JKM440N-54HL4R-B is STC power, measured at 1000 W/m² and 25 °C cell temperature.
Datasheet: Pmax temperature coefficient −0.29%/°C; 331 W at NOCT (800 W/m², 20 °C air, 1 m/s wind).
Worked example: 440 W × (1 − 0.0029 × 40) ≈ 389 W with cells at 65 °C. That is a calculation from the datasheet coefficient at an example cell temperature, not a measurement.
Real cell temperature depends on irradiance, wind and mounting, so compare output against irradiance and module temperature, not against the label.
Installer tip: keep the ventilation gap under the modules (JinkoSolar asks for at least 10 cm) and check the Pmax coefficient when choosing modules; closer to 0 is better.
Source
Where installers ask this
- Texas heat and greatly reduced output from panels (r/SolarDIY)
- reddit.com/r/SolarDIY/comments/1vnztj8/system_severely_underperforms_when_its_hot_how/
- Distance between roof and solar panel? (r/vandwellers)
- reddit.com/r/vandwellers/comments/v2i77q/airflow_beneath_solar_panel/
The full answer
- QS-111 · Sunny July noon and my 440 W modules only make about 390 W each. Are they faulty?
- QS-112 · How much air gap do I need between the modules and the roof?
How many watts do your modules really make on the hottest day?
Ask a question →