Wait for modules to dry, check the ISO protection value, measure string resistance to ground and check battery cables.

Plain explanation

From the Sungrow manual for the SH-RT hybrid: Wait – it may clear when modules dry. Installer checks the ISO protection value in the app is not set too high. The rest of the checklist is below; work through it in order. Installer only: DC and AC work on a live PV system is dangerous, so owners should note the code and call their installer.

Steps from the source

  1. Wait – it may clear when modules dry
  2. Installer checks the ISO protection value in the app is not set too high
  3. Installer measures string/DC cable resistance to ground
  4. If it only appears on rainy days, recheck on a dry day
  5. Check battery cables/terminals
  6. Persists → Sungrow service

Source

Sungrow SH5.0-10RT User Manual Ver21, §10.1 Troubleshooting, §10.1 p137info-support.sungrowpower.com ↗