Victron MPPT stops charging with Err 38 PV input shutdown. How do I recover it?
Update firmware, check battery voltage setting and other chargers, then disconnect panels and battery for 3 min.
7 answers · 4 products. Not affiliated with or endorsed by Victron; trademarks belong to their owners.
We do not invent answers. Leave your question and we will find a real installer thread and a primary source, quote word for word, and publish only after review.
Your question is in the queue. Nothing is published automatically; every new answer is checked against a real source first.
Inverters · 4 answers
Update firmware, check battery voltage setting and other chargers, then disconnect panels and battery for 3 min.
Check the charger-BMS link; with no BMS, set LCD setup 31 BMS to N or factory-reset in VictronConnect.
It auto-resets: check other charging equipment and that the battery voltage setting isn't lower than the battery.
It auto-resets, but if string Voc is critical the installer must re-organise the panels.
Inverters · 1 answer
Update all firmware, configure as one system, replace RJ45 cables with factory ones and check the DC fuse.
Inverters · 1 answer
Update firmware, check AC-in wiring and earth, test AC-out loads, and check neutral-out and input L/N.
Hybrid & backup systems · 1 answer
Look at the ESS minimum SOC first: ESS recharges from the grid when the SOC falls 5 % or more below it. In winter BatteryLife also raises the low limit by 5 % a day. Also check whether a scheduled charge or a BMS request was active.