The short answer
Update firmware, check AC-in wiring and earth, test AC-out loads, and check neutral-out and input L/N.
Plain explanation
From the Victron manual for the MultiPlus-II: Update FW. Check wiring/earth on AC in. The rest of the checklist is below; work through it in order. Installer only: DC and AC work on a live PV system is dangerous, so owners should note the code and call their installer. Grid limits depend on your country, so check your national code and grid operator rules.
Steps from the source
- Update FW
- Check wiring/earth on AC in
- Disconnect L/N ACout to test loads
- Neutral-out no external link
- L/N input inverted
Source
Victron VE.Bus error codes (official docs), Err 11www.victronenergy.com ↗
Where installers ask this
- Multiplus 3 phase relay test issue error 11 (r/Victron)
- reddit.com/r/Victron/comments/1ak62gw/
- reddit.com/r/Victron/comments/1lhfymg/
General guidance based on the manufacturer's manual or the named source. Always follow the current manual for your exact model and your national code. DC and AC electrical work is for qualified installers only. Not affiliated with or endorsed by any brand named; trademarks belong to their owners.