GoodWe ISO error: what insulation reading should a string have?
The manual's check: PV string-to-PE resistance above 50 kΩ; also check PE. Rain-only faults may need a threshold reset.
4 answers · 1 product. Not affiliated with or endorsed by GoodWe; trademarks belong to their owners.
We do not invent answers. Leave your question and we will find a real installer thread and a primary source, quote word for word, and publish only after review.
Your question is in the queue. Nothing is published automatically; every new answer is checked against a real source first.
Inverters · 4 answers
The manual's check: PV string-to-PE resistance above 50 kΩ; also check PE. Rain-only faults may need a threshold reset.
Check grid voltage and contact the power company; OV threshold or HVRT may change only with their consent.
ON = both OK, BLINK 1 = BMS comms failed, BLINK 2 = meter comms failed, OFF = both failed.
Check household load is above about 150 W, SOC vs DOD, the charge time window and meter/CT direction.