Deye F23 leakage current / F24 DC insulation impedance. Where do I look?
Check PV cable insulation to ground, PV connections and PE; restart 2–3 times; persistent means support.
7 answers · 3 products. Not affiliated with or endorsed by Deye; trademarks belong to their owners.
We do not invent answers. Leave your question and we will find a real installer thread and a primary source, quote word for word, and publish only after review.
Your question is in the queue. Nothing is published automatically; every new answer is checked against a real source first.
Inverters · 5 answers
Check PV cable insulation to ground, PV connections and PE; restart 2–3 times; persistent means support.
Check the inverter-BMS comm cable and battery protocol settings; BMS_Err-Stop can be disabled only if no BMS comms is intended.
Usually low battery voltage: charge the battery from PV or grid and check the battery is on.
Backup load is above the inverter rating: remove big loads, restart, then escalate if it persists.
Usually clears after a grid type or battery-mode change; otherwise switch DC and AC off for 1 minute.
Inverters · 1 answer
Don't keep restarting after a bang. Isolate it, check what the manual tells you to check (PV voltage, battery polarity, AC wiring), then have the installer or Deye inspect it. In this case Deye found a faulty power/driver board.
Inverters · 1 answer
Yes. Deye's 'Grid Peak-shaving' caps grid import at a set value and covers the rest from PV and battery. The 30 % 'time of use' floor applies while the grid is there. In a grid outage the battery runs on to the shutdown limit.