Supply 48–53.5 V and charge gently (≤0.05C at or below 45 V); if it doesn't recover, it goes to repair.
Plain explanation
From the Pylontech manual for the US5000: Installer supplies 48–53.5 V. ≤45 V: charge at ≤0.05C. The rest of the checklist is below; work through it in order. Installer only: DC and AC work on a live PV system is dangerous, so owners should note the code and call their installer.
Steps from the source
- Installer supplies 48–53.5 V
- ≤45 V: charge at ≤0.05C
- Above 45 V: ≤0.5C
- Doesn't recover → repair via distributor
Source
Pylontech US5000/US5000-B Installation Manual V1.0 (2024-09), Troubleshooting, Troubleshooting, printed p27-29pylonwebs3.s3.amazonaws.com ↗