QS-057 · Battery start-up, charging & protection

BYD battery deeply discharged (EC110 low voltage). Can I save it?

The short answer
Shut it down to stop further discharge, see if the inverter can force-charge, measure voltage and contact BYD service.

Plain explanation

From the BYD manual for the Battery-Box Premium HVS/HVM: Shut the battery down – avoid further discharge. Check whether the inverter can force-charge. The rest of the checklist is below; work through it in order. This is a warranty/support case: note the code, time and serial number before calling the manufacturer.

Steps from the source

  1. Shut the battery down – avoid further discharge
  2. Check whether the inverter can force-charge
  3. Installer measures voltage; cell <1.5 V = undervoltage
  4. Contact BYD service with the checklist

Source

BYD Battery-Box Premium HVS/HVM Service Guideline & Checklist (BCU2.0) V1.1, 2025-08-08, §2.9 EC110 + §2.10www.bydbatterybox.com ↗